Differential pressure sensor Deltronic
Temperature and pressure under control
The differential pressure sensor continuously monitors oil filters in hydraulic systems. At the same time, it controls the oil temperature. The sensor is available for different pressure and temperature ranges.

Deltronic
How we measure success: Your advantages.
Mechanical differential pressure monitoring
For high and unstable system pressures
High system pressure
Measurements possible at very high system pressures
Small hysteresis with low leakage rate
With only 0.1 ml leak rate at 250 kPa differential pressure
High measuring accuracy
Through multi-point calibration
Long-term stability
Possible through mechanical pressure measurement
Long product life cycles
Designed for industrial use with long-term spare parts availability
Technology at a glance
See here how the differential pressure sensor is constructed and which components make up its functionality. We will be happy to show you more live or online during a personal consultation.


Technical information
Accurately measure low differential pressures at high system pressures. The differential pressure sensor Deltronic was developed for efficient and long-term stable differential pressure measurement. Thanks to the mechanical differential pressure monitoring, the sensor can be used at very high and non-stable system pressures.
Other features:
- High differential overpressure resistance
- Status display
- 2 switching outputs in the following ranges:
1.82 to 2.46 bar
2.40 to 3.38 bar
5.21 to 7.07 bar - Alternatively 1 switching output and one analog output 4 to 20 mA
- Protection class IP68
Available types:
- Deltronic HZ9790ZHxx-DC/DCYD
- xx= 2.4 / 3.4 or 6.9 bar
- DC = with cold start suppression at 27°C
- DCYD = without cold start suppression
- Deltronic HZ9788ZHxx-DB/ DBYD
- xx= 2.4 / 3.4 and 6.9 bar
- DB = with cold start suppression at 27°C
- DBDY = without cold start suppression
- Analog Deltronic HZ0856Dxxxwith analog output 4-20mA)
- xxx = 2.5 / 4.0 / 8.0 bar
Supply | 12 – 28 V / < 60 mA |
Output signal | 4–20 mA |
Alarm output | High-Side switch VCC / 200 mA |
Status display | Yes |
Protection class | IP68 |
Threaded connection | 3/4“ – 16 UNF – 3A |
Mass | 160 g |
Available types
Deltronic HZ9790ZH24-DC | 2.4 bar | with cold start suppression at 27 °C |
Deltronic HZ9790ZH34-DC | 3.4 bar | with cold start suppression at 27 °C |
Deltronic HZ9790ZH69-DC | 6.9 bar | with cold start suppression at 27 °C |
Deltronic HZ9792ZH24-DC | 2.4 bar | with cold start suppression at 37°C |
Deltronic HZ9792ZH34-DC | 3.4 bar | with cold start suppression at 37 °C) |
Deltronic HZ9792ZH69-DC | 6.9 bar | with cold start suppression at 37°C |
Deltronic HZ9790ZH24-DCYD | 2.4 bar | without cold start suppression |
Deltronic HZ9790ZH34-DCYD | 3.4 bar | without cold start suppression |
Deltronic HZ9790ZH69-DCYD | 6.9 bar | without cold start suppression |
Deltronic HZ9788ZH24-DB | 2.4 bar | with cold start suppression at 27 °C |
Deltronic HZ9788ZH34-DB | 3.4 bar | with cold start suppression at 27 °C |
Deltronic HZ9788ZH69-DB | 6.9 bar | with cold start suppression at 27 °C |
Deltronic HZ9788ZH24-DBYD | 2.4 bar | without cold start suppression |
Deltronic HZ9788ZH34-DBYD | 3.4 bar | without cold start suppression |
Deltronic HZ9788ZH69-DBYD | 6.9 bar | without cold start suppression |
Deltronic HZ9788ZH24-DC | 2.4 bar | with cold start suppression at 27 °C |
Deltronic HZ9788ZH34-DC | 3.4 bar | with cold start suppression at 27 °C |
Deltronic HZ9788ZH69-DC | 6.9 bar | with cold start suppression at 27 °C |
Deltronic HZ9788ZH24-DCYD | 2.4 bar | without cold start suppression |
Deltronic HZ9788ZH34-DCYD | 3.4 bar | without cold start suppression |
Deltronic HZ9788ZH69-DCYD | 6.9 bar | without cold start suppression |
Analog-Deltronic HZ0856D800 | 8.0 bar | with analogue output 4-20mA |
Analog-Deltronic HZ0856D400 | 4.0 bar | with analogue output 4-20mA |
Analog-Deltronic HZ0856D250 | 2.5 bar | with analogue output 4-20mA |
Service
How is the product maintained?
We recommend an annual recalibration and adjustment for all our sensors to be able to guarantee the exact functionality. We calibrate our sensors with state-of-the-art measurement technology in our in-house calibration laboratory. Our test equipment is one of the most accurate references in measurement and control technology. The test results are summarised in a factory calibration certificate in accordance with DIN EN ISO/IEC 17025:2018-03.

Ready for download
Simply download the latest product information here. Do you have further questions about iocto and our products? We are happy to be there for you.